Mycoplasma Hominis Nucleic Acid

Apejuwe kukuru:

Ohun elo yii dara fun wiwa ti agbara ti Mycoplasma hominis (MH) ninu ito ọkunrin ati awọn ayẹwo yomijade abo abo.


Alaye ọja

ọja Tags

Orukọ ọja

HWTS-UR004A-Mycoplasma Hominis Ohun elo Iwari Acid Nucleic (Pluorescence PCR)

Arun-arun

Awọn arun ti ibalopọ takọtabo (STDs) tun jẹ ọkan ninu awọn irokeke pataki si aabo ilera gbogbogbo agbaye, eyiti o le ja si aibikita, ibimọ ọmọ inu oyun, tumorigenesis ati ọpọlọpọ awọn ilolu pataki.Mycoplasma hominis wa ninu apa genitourinary ati pe o le fa awọn idahun iredodo ni apa genitourinary.Ikolu MH ti apa genitourinary le fa awọn arun bi urethritis ti kii-gonococcal, epididymitis, ati bẹbẹ lọ, ati laarin awọn obinrin, eyiti o le fa igbona ti eto ibisi ti o tan kaakiri lori cervix.Ni akoko kanna, ilolura ti o wọpọ ti ikolu MH jẹ salpingitis, ati pe nọmba kekere ti awọn alaisan le ni endometritis ati arun iredodo ibadi.

ikanni

FAM MH afojusun
VIC(HEX) Iṣakoso ti abẹnu

Imọ paramita

Ibi ipamọ Omi: ≤-18℃ Ninu okunkun
Selifu-aye 12 osu
Apeere Iru awọn aṣiri ito, awọn ifasilẹ ti ara
Ct ≤38
CV 5.0%
LoD 1000 Awọn ẹda/ml
Ni pato Ko si ifaseyin-agbelebu pẹlu awọn pathogens ikolu STD miiran, eyiti o wa ni ita ibiti a ti rii, ati pe ko si ifaseyin agbelebu pẹlu chlamydia trachomatis, ureaplasma urealyticum, neisseria gonorrhoeae, mycoplasma genitalium, Herpes simplex virus type 1, Herpes simplex virus type 2 , ati be be lo.
Awọn ohun elo ti o wulo O le baramu awọn ohun elo PCR Fuluorisenti akọkọ lori ọja naa.

Applied Biosystems 7500 Yara Real-Time PCR Systems

QuantStudio®5 Real-Time PCR Systems

SLAN-96P Real-Time PCR Systems

LightCycler®480 Real-Time PCR eto

LineGene 9600 Plus Real-Time PCR erin System

MA-6000 Real-Time Quantitative Gbona Cycler

BioRad CFX96 Real-Time PCR System

BioRad CFX Opus 96 Real-Time PCR System

Sisan iṣẹ

Aṣayan 1.

Niyanju isediwon reagent: Makiro & Micro-Test Ayẹwo Tu Reagent (HWTS-3005-8).Iyọkuro yẹ ki o ṣe ni ibamu pẹlu awọn ilana.

Aṣayan 2.

Niyanju isediwon reagent: Makiro & Micro-Test Viral DNA/RNA Kit (HWTS-3017-50, HWTS-3017-32, HWTS-3017-48, HWTS-3017-96) (eyi ti o le ṣee lo pẹlu Makiro & Micro-Igbeyewo. Iyọkuro Acid Nucleic Acid Aifọwọyi (HWTS-3006C, HWTS-3006B)) nipasẹ Jiangsu Macro & Micro-Test Med-Tech Co., Ltd. Isediwon yẹ ki o waiye ni ibamu si awọn ilana naa.Iwọn didun elution ti a ṣe iṣeduro yẹ ki o jẹ 80 μL.

Aṣayan 3.

Reagent isediwon ti a ṣe iṣeduro: Iyọkuro Acid Nucleic Acid tabi Reagent Iwẹnumọ (YDP302) nipasẹ Tiangen Biotech (Beijing) Co., Ltd.