Trichomonas Vaginalis Nucleic Acid
Orukọ ọja
HWTS-UR011A-Trichomonas Vaginalis Apo Iwari Acid Nucleic Acid (Imudara Isothermal)
Arun-arun
Trichomonas vaginalis (TV) jẹ parasitic flagellate kan ninu obo eniyan ati eto ito, eyiti o fa trichomonas vaginitis ati urethritis ni pataki, ati pe o jẹ arun ti ibalopọ ti o tan kaakiri.Trichomonas vaginalis ni isọdọtun to lagbara si agbegbe ita, ati pe gbogbo eniyan ni ifaragba.O fẹrẹ to miliọnu 180 awọn eniyan ti o ni akoran kaakiri agbaye, ati pe oṣuwọn ikolu naa ga julọ laarin awọn obinrin ti o wa ni ọdun 20 si 40. Ikolu Trichomonas vaginalis le mu ifaragba si ọlọjẹ ajẹsara eniyan (HIV), papillomavirus eniyan (HPV), ati bẹbẹ lọ Awọn iwadii iṣiro ti o wa tẹlẹ fihan pe Trichomonas vaginalis ikolu jẹ ibatan pẹkipẹki pẹlu oyun ti ko dara, cervicitis, infertility, ati bẹbẹ lọ, ati pe o ni ibatan si iṣẹlẹ ati asọtẹlẹ ti awọn èèmọ buburu ti ibisi bi akàn ti ara, akàn pirositeti, bbl Ayẹwo deede ti Trichomonas vaginalis ikolu jẹ ọna asopọ pataki pataki. ni idena ati itọju arun na, ati pe o ṣe pataki pupọ lati ṣe idiwọ itankale arun na.
ikanni
FAM | TV nucleic acid |
ROX | Iṣakoso ti abẹnu |
Imọ paramita
Ibi ipamọ | Omi: ≤-18℃ |
Selifu-aye | osu 9 |
Apeere Iru | itosi ito, itosi inu |
Tt | <30 |
CV | ≤10.0% |
LoD | 3 awọn ẹda/µL |
Ni pato | Ko si ifaseyin agbelebu pẹlu awọn ayẹwo iṣan urogenital miiran, gẹgẹ bi Candida albicans, Chlamydia trachomatis, Ureaplasma urealyticum, Neisseria gonorrhoeae, Group B streptococcus, Mycoplasma hominis, Mycoplasma genitalium, Herpes simplex virus, Human papillomavirus vaginvirus, Emumi-ara-ara-ara-ara-ara-ara-ara, Garalcoplasma streptococcus. Human Genomic DNA, ati be be lo. |
Awọn ohun elo ti o wulo | Rọrun Amp Gidigidi Fluorescence Eto Wiwa Isothermal (HWTS 1600) Applied Biosystems 7500 Real-Time PCR System Applied Biosystems 7500 Yara Real-Time PCR Systems QuantStudio®5 Real-Time PCR Systems SLAN-96P Real-Time PCR Systems LightCycler®480 Real-Time PCR eto LineGene 9600 Plus Real-Time PCR erin System MA-6000 Real-Time Quantitative Gbona Cycler BioRad CFX96 Real-Time PCR System BioRad CFX Opus 96 Real-Time PCR System |
Sisan iṣẹ
Aṣayan 1.
Niyanju isediwon reagent: Makiro & Micro-Test Ayẹwo Tu Reagent (HWTS-3005-8) ti a ṣe nipasẹ Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.
Aṣayan 2.
Niyanju isediwon reagent: Makiro & Micro-Test Viral DNA/RNA Kit (HWTS-3001, HWTS-3004-32, HWTS-3004-48, HWTS-3004-96) ati Makiro & Micro-Idanwo Aifọwọyi Nucleic Acid Extractor (HWTS-) 3006) ti a ṣe nipasẹ Jiangsu Macro & Micro-Test Med-Tech Co., Ltd.